Modified electrocardiograph-triggered black-blood turbo spin-echo technique to improve T1-weighting in contrast-enhanced MRI of atherosclerotic carot…
2008
Purpose To assess the efficacy of a modified electrocardiograph (EKG)-triggered black-blood T1W (T1W) spin-echo sequence in improving contrast on post-gadolinium high-resolution carotid plaque imaging by implementing heart-rate–independent contrast preparation. Materials and Methods We used a standard EKG-triggered double inversion-recovery (DIR) turbo spin-echo (TSE) sequence modified with the addition of an extra saturation (90°) radio frequency (RF) pulse placed immediately after the DIR module, shortening the repetition time to a fixed value of 400 msec. A total of 10 patients with atherosclerotic disease were included in the study. Postinjection intraplaque contrast measurements were p…
Fast Spin Echo e Spin-Echo
1994
Uno dei maggiori problemi connessi alio studio del SNC di pazienti in età pediatrica con RM è indubbiamente costituito dalla durata dell'esame stesso, che impone sovente la necessità di una sedazione farmacologica del paziente e limita allo stretto indispensabile il numero delle acquisizioni effettuate. Appare pertanto facilmente intuibile l'entusiasmo rivolto verso nuovi tipi di sequenze che presentino quale caratteristica principale una drastica riduzione dei tempi di acquisizione pur mantenendo un'affidabile qualità diagnostica. Le sequenze di tipo Fast-Spin-Echo (FSE) costituiscono il successivo sviluppo delle sequenze denominate RARE (Rapid Acquisition Relaxation Enhanced) descritte d…
Preliminary experience with a transcranial magnetic resonance-guided focused ultrasound surgery system integrated with a 1.5-T MRI unit in a series o…
2018
OBJECTIVETranscranial magnetic resonance–guided focused ultrasound surgery (tcMRgFUS) is one of the emerging noninvasive technologies for the treatment of neurological disorders such as essential tremor (ET), idiopathic asymmetrical tremor-dominant Parkinson’s disease (PD), and neuropathic pain. In this clinical series the authors present the preliminary results achieved with the world’s first tcMRgFUS system integrated with a 1.5-T MRI unit.METHODSThe authors describe the results of tcMRgFUS in a sample of patients with ET and with PD who underwent the procedure during the period from January 2015 to September 2017. A monolateral ventralis intermedius nucleus (VIM) thalamic ablation was pe…
Comparison of Single-Echo T2-weighted Fast Spin-Echo and Conventional Spin-Echo MR Sequences
1998
We compared single-echo T2-weighted fast spin-echo (FSE) magnetic resonance imaging and conventional spin-echo (CSE) T2-weighted imaging in the detection of brain lesions of multiple sclerosis (MS). 16 patients with clinically definite MS underwent brain imaging at 0.5 T with T2-weighted single-echo fast spin-echo (FSE) and conventional spin-echo (CSE) sequences. Image analysis was performed by three of the investigators who worked together to reduce interobserver variability. Statistical analysis was performed using Student's t test to assess the difference in the contrast-to-noise (C/N) ratio of MS lesions between CSE and FSE sequences. The Wilcoxon signed rank test was used to evaluate …
MRI of the inner ear: use of modified GRASS and fast spin-echo sequences
1996
We report our experience with MRI of the normal and pathological inner ear with fast spin-echo and modified gradient recalled at steady state sequences. Although earlier studies on temporal bone MRI were discouraging, improvements in MR technology combined with the use of paramagnetic contrast media can make MRI a useful diagnostic tool for the assessment of inner ear pathology. Conventional spin-echo imaging seems not to be the modality of choice because of the relatively thick slices and the long acquisition times.